{"title":"Residual Gas Analyzers","description":"\u003cp\u003eResidual Gas Analyzers are an effective tool to analyze system gas loads resulting from real leaks, virtual leaks or chamber wall outgassing. RGAs have a number of advantages over traditional, dedicated gas leak detectors including the ability to differentiate between different gas species, comparable sensitivity levels, the ability to detect internal or \"virtual\" leaks and to detect and analyze outgassing problems.\u003c\/p\u003e","products":[{"product_id":"microvision-2","title":"Microvision 2","description":"\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eMicrovision 2 is useful in a wide range of situations where knowing the contents of your chamber is critical to the success of your process:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemiconductor Manufacturing\u003c\/li\u003e\n\u003cli\u003eLarge Scale Coating Tools\u003c\/li\u003e\n\u003cli\u003eHigh Mass Performance\u003c\/li\u003e\n\u003cli\u003eUltra-High Vacuum\u003c\/li\u003e\n\u003cli\u003eHarsh Environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Microvision 2 can be used to broaden the range of applications where RGA provides value to advanced process control systems. It is available as the core technology in a variety of generic and customised process gas measurements systems. To discuss any specific vacuum, low pressure or atmospheric pressure applications where knowledge of the gas species levels would provide critical value to your processes, please contact your local MKS Instruments representative. They will be able to call on MKS' global RGA applications expertise to provide the optimum solution to improve the effectiveness of your process control systems.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0120\/5321\/7338\/files\/MicroVision2ds.pdf?v=1620407484\" rel=\"noopener\" target=\"_blank\"\u003eDownload data sheet for more information\u003c\/a\u003e\u003c\/p\u003e","brand":"VACPRO - Vacuum Process Solutions","offers":[{"title":"Default Title","offer_id":57548095291774,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0120\/5321\/7338\/files\/image_77_7bc6a31f-2ff6-4eb2-af12-ec76a6f88a7d.png?v=1781508927"},{"product_id":"e-vision-2","title":"e-Vision 2","description":"\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLeak detection of vacuum lines, welds and seals\u003c\/li\u003e\n\u003cli\u003eVacuum diagnostics\u003c\/li\u003e\n\u003cli\u003ePump down monitoring\u003c\/li\u003e\n\u003cli\u003eChamber bake out monitoring\u003c\/li\u003e\n\u003cli\u003eLeak checking of coolant lines within a vacuum chamber\u003c\/li\u003e\n\u003cli\u003eChamber contaminant monitoring\u003c\/li\u003e\n\u003cli\u003eMonitor cryo-pump performance\u003c\/li\u003e\n\u003cli\u003eMonitor getter performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003edescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHardware:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensors:\u003c\/strong\u003e Field proven MKS quadrupole mass analyzers, with twin filaments as standard, ensure minimum downtime during critical diagnostic testing. The RGA is available with an optional dual detector including a faraday detector and microchannel plate electron multiplier for detection to e-14 mbar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronics:\u003c\/strong\u003e Data acquisition occurs through all solid state, wide dynamic range, fast settling detector electronics. This technology prevents large peaks from causing false positive measurements on small peaks. Temperature stabilized critical components mean that signal stability and baseline drift are improved, allowing the unit to be used without frequent recalibration if the vacuum chamber is stable but ambient air temperature fluctuates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSoftware\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Web Application : \u003c\/strong\u003eA web interface using industry standard technology allows control of the e-Vision 2 as well as calibration, operation and data export through a non platform-specific web browser from anywhere on a network. Using the ASCII protocol and TCP-IP communication, any third party software can send and receive commands and data from the e-Vision 2. In addition to the standard, built-in web applications, software control is also available through an optional Windows™ application, offering the best possible fit to any customer requirement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasyView:\u003c\/strong\u003e The field proven software provides basic RGA controls but with more functionality than the built-in web application:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStore RGA data and recall it back into the Recall viewer\u003c\/li\u003e\n\u003cli\u003eAnnotate graphs with notes\u003c\/li\u003e\n\u003cli\u003eRun several RGAs from one software package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0120\/5321\/7338\/files\/eVision2ds.pdf?v=1620407484\" target=\"_blank\" rel=\"noopener\"\u003eDownload data sheet for more information\u003c\/a\u003e\u003c\/p\u003e","brand":"VACPRO - Vacuum Process Solutions","offers":[{"title":"Default Title","offer_id":57548236390782,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0120\/5321\/7338\/files\/image_80_04d394f8-2bdc-4139-a161-628a43df223d.png?v=1781510275"},{"product_id":"hpq3-hpq3s","title":"HPQ3 \u0026 HPQ3S","description":"\u003ch2\u003eFeatures \u0026amp; Benefits:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEasily installed\u003c\/li\u003e\n\u003cli\u003eWeb interface for setup and control on any network\u003c\/li\u003e\n\u003cli\u003eHigh reliability \u0026amp; low cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe HPQ3 and HPQ3S are suitable for a wide range of applications in PVD or for vacuum systems with inert residual gases including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLeak detection\u003c\/li\u003e\n\u003cli\u003eVacuum diagnostics\u003c\/li\u003e\n\u003cli\u003ePump down monitoring\u003c\/li\u003e\n\u003cli\u003eProcess monitoring\u003c\/li\u003e\n\u003cli\u003eRate-of rise testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0120\/5321\/7338\/files\/HPQ3-DS.pdf?v=1620407484\" target=\"_blank\" rel=\"noopener\"\u003eDownload data sheet for more information\u003c\/a\u003e\u003c\/p\u003e","brand":"VACPRO - Vacuum Process Solutions","offers":[{"title":"Default Title","offer_id":57548339347838,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0120\/5321\/7338\/files\/image_81_9ee59bb6-874c-4a27-aca5-67fc1aea76c3.png?v=1781511950"}],"url":"https:\/\/vacpro.co.uk\/collections\/residual-gas-analyzers.oembed","provider":"VACPRO - Vacuum Process Solutions","version":"1.0","type":"link"}